Expertise

Design controls & regulatory

I help teams keep design controls, usability and the quality system in a state that holds up to an FDA inspection or a notified-body audit, and assemble software documentation that reads as one coherent story in a submission.

A design review: people marking up requirements documents beside a device prototype
Design controls from user needs to the deviceUser needs become design inputs, the design process produces design outputs, and the outputs become the medical device. Verification checks outputs against inputs; validation checks the device against user needs. Design reviews happen along the way, and design transfer moves the design into production.User needsDesign inputDesign processDesign outputMedical deviceVerificationoutputs meet inputsValidationdevice meets needsDesign reviews at each stage · design transfer to production · design history file
Design controls: verification checks outputs against inputs, validation checks the device against user needs.

When teams bring me in

  • You're preparing a 510(k), De Novo or PMA and need the software documentation reviewed or assembled
  • Your procedures still reflect the old QSR and need to match the QMSR and ISO 13485
  • A design review, audit or inspection is coming and you want an independent read first
  • Usability work and the risk file don't line up

What you get

  • Design control procedures and DHF/medical device file review
  • QMSR gap assessment and remediation plan
  • Internal audit reports
  • Usability engineering file review
  • Software documentation package for submission
  • Deficiency letter responses

How I help

Design controls

Design and development planning, inputs, outputs, reviews, verification, validation, transfer and change control, mapped cleanly to your software lifecycle.

QMSR and ISO 13485

Gap assessments against ISO 13485:2016 and FDA's QMSR additions, procedure updates, and internal audits run to lead-auditor standard.

Usability engineering

Use specifications, critical tasks and hazard-related use scenarios tied into the risk file, and review of human factors reports before submission.

Submission documentation

Documentation level decisions (Basic vs Enhanced), pre-submission gap reviews, and responses to additional information requests.

Case study

Launching a new interventional laser system and its EU MDR file at the same time

The fault tree showed empirically that the software didn't add risk to the device, answering FDA's question with data instead of argument.

Read the case study →

How engagements work

Most work starts with a short call and a fixed-scope assessment, then moves to a project or a monthly retainer. I work remotely, with on-site time when it helps; travel is billed as set out in the engagement agreement.

Related guides: QMSR (21 CFR 820) · IEC 62366-1 · FDA software guidance

You're in

Thanks, you're in. Check your inbox.

Cookies on this site

Essential storage keeps the site working and remembers this choice. With your OK, I'd also use HubSpot to see which articles and tools are useful, and to show my booking calendar on the contact page. Nothing optional loads until you choose, and you can change your mind anytime from Cookie settings at the bottom of every page.

What each option does
Accept all
Essential storage, the HubSpot booking calendar, and HubSpot analytics cookies.
Essential only
Essential storage and the HubSpot booking calendar, which sets its own cookies when it loads on the contact page. No analytics.
Deny
Only what's needed to remember this choice. No analytics, and the booking calendar stays off until you click to load it.

Privacy policy: cookies and analytics